- LABVIEW 8.5 SERIAL NUMBER INSTALL
- LABVIEW 8.5 SERIAL NUMBER SERIAL
- LABVIEW 8.5 SERIAL NUMBER DRIVER
- LABVIEW 8.5 SERIAL NUMBER FULL
- LABVIEW 8.5 SERIAL NUMBER SERIES
Refer to the chart of Supported Interfaces for detailed model information.
LABVIEW 8.5 SERIAL NUMBER SERIAL
NI-Serial for LabVIEW Real-Time, Version 3.6, adds support for National Instruments PXI Express serial interfaces. To reset these settings to default, delete the niserial.dbs file from the Real-Time target.Ĭhanges and Fixed Issues in Version 3.6 Add support for PXI Express serial hardware The modifications to the niserial.dbs file will also persist through reinstalls of the NI-Serial driver. Serial settings stored in the niserial.dbs file, including port numbers, will persist after uninstalling NI-Serial 3.7 from a Real-Time target. Please refer to Changes and Fixed Issues in NI-Serial 3.8 for more information. The behavior of settings on uninstall has been reverted in NI-Serial 3.8. For more information go to ni.com/kb and search for 5D2G85G2. Under some circumstances inserting new boards into a system may cause port numbers to change. NI-Serial 3.7 changes the way that ports are numbered when detecting boards. For more information go to ni.com/kb and search for 5DTFTOL1. If using NI-RIO 3.5.x and lower, you may see warning pop-ups indicating that the NI 987x modules are not supported on RSI. When detecting the modules, users will have the option to add the module directly to the chassis in the LabVIEW project.
LABVIEW 8.5 SERIAL NUMBER INSTALL
To enable this support, install NI-Serial 3.7 and NI-VISA for LabVIEW Real-Time on a Compact RIO Target that supports RIO Scan Interface (RSI). NI-Serial 3.7 allows users to access the NI 98 modules directly from LabVIEW Real-Time 2010 without using the LabVIEW FPGA interface. NI-Serial for LabVIEW Real-Time, Version 3.7.1, adds support for the NI cRIO-9075 and cRIO-9076 Controllers.Ĭhanges and Fixed Issues in Version 3.7 NI 98 Modules
This has been fixed.Ĭhanges and Fixed Issues in Version 3.7.1 Add support for the NI cRIO-9075/6 Controller In some rare circumstances, the process of shutting down serial ports for a reboot could cause the controller to hang.
LABVIEW 8.5 SERIAL NUMBER SERIES
It was possible for a cRIO controller to crash during reboot when using serial ports on a C Series module.
ID 288079: Possible crash when rebooting cRIO while using NI 987 x modules
LABVIEW 8.5 SERIAL NUMBER FULL
When the RX FIFO became completely full on some cRIO, sbRIO, and cFP controllers, the port could stop receiving data. This valid data is now properly received prior to handling the error condition. Several bytes of valid data could be discarded immediately prior to the reception of a serial error, such as a parity or overrun error. ID 287461: Possible loss of data preceding serial error When using multiple forms of flow control simultaneously on a single port, it was possible for flow control to fail to disengage, preventing data transmission. ID 288089: Flow control may not disengage Mark and space parity were not properly configured on some cRIO, sbRIO, and cFP controllers. These controllers will continue to work with previous versions of NI-Serial. It is not possible to install on FP-20 xx or cFP-20 xx controllers. NI-Serial for LabVIEW Real-Time, Version 3.8, requires LabVIEW Real-Time 8.6 or later. Removed support for FP-20 xx and cFP-20 xx controllers. This matches the behavior of NI-Serial 3.6 and earlier. This has the effect that any customized settings will be removed. The niserial.dbs file is replaced each time NI-Serial is uninstalled or reinstalled. NI-Serial settings no longer persist after uninstall On these systems, PnP hardware will now be assigned port numbers starting with COM3, when they may have previously been assigned COM2. NI-Serial now reserves port numbers for two built-in serial ports on all PXI, Industrial Controller, Desktop RT, and cRIO-908x controllers. NI-Serial 3.8 adds support for additional cRIO, sbRIO, and Smart Camera controllers. Several enhancements have been made to improve performance and decrease CPU overhead when performing small writes on all interfaces, and small reads on 843x series hardware.
Every attempt has been made to maintain backward compatibility with the installed base of existing NI-Serial applications.Ĭhanges and Fixed Issues in Version 3.8 Performance Optimizations for Small Transfers
LABVIEW 8.5 SERIAL NUMBER DRIVER
NI-Serial for LabVIEW Real-Time, Version 3.8, is the latest driver offering from National Instruments.